Fluorescence Analyzers Evaluated for Diagnoses of UTIs

By LabMedica International staff writers
Posted on 10 Sep 2018
Print article
Image: The UF-5000 Urine fluorescence flow cytometry analyzer (Photo courtesy of Sysmex).
Image: The UF-5000 Urine fluorescence flow cytometry analyzer (Photo courtesy of Sysmex).
Urinary tract infections (UTIs) are among the most frequent infections in both hospitalized and outpatients. As a result, urine specimens constitute a significant proportion of routine microbiology laboratory workload.

Traditional culture remains the “gold standard” for the diagnostic evaluation of patients suspected of having a UTI as it allows the identification of the etiological agents, to estimate the concentration of isolated microorganisms and to offer susceptibility testing for targeting the optimal antibiotic therapy.

Medical microbiologists at the Pordenone Hub Hospital (Pordenone, Italy) evaluated 2,719 midstream urine samples from 1,198 (44.1%) male and 1,521 (55.9%) female, aged from 0 and 97 years (median age = 66 years), submitted to the microbiology laboratory with a specific request for urine culture. Inpatients were 23.9% and outpatients 76.1%. The study was conducted from April 6 to June 12, 2017.

All specimens that passed an exclusion criterion were analyzed with the Sysmex UF-5000 (Sysmex Corporation, Kobe, Japan). The analyzer can discriminate and count 17 diagnostic parameters of cells and formed elements in urine and offers an integrated body fluid mode (BF), available on the instrument with a switch, which can classify and count seven diagnostic parameters. The system employs fluorescence flow cytometry technology, using a new blue semi-conductor laser at 488 nm wavelength, Gram staining of centrifuged specimens was conducted in case of discrepancies between the results of the UF-5000 Bact Info flag and the culture method.

The scientists reported that of the 2,719 samples, 1,922 (70.7%) were negative in urine culture (sterile or ≤ 104 CFU/mL) and 797 (29.3%) showed significant growth. In 574 of the positive samples a single microorganism was identified, in 71 samples two microorganisms were isolated, and 152 samples showed mixed flora. The microorganisms isolated reflected the usual rate of uropathogens in their laboratory, so that the most frequent bacteria reported were Gram negatives accounting for 76.9% of all species isolated, and the majority were Enterobacteriaceae. The UF-5000 showed a very good performance in the screening process. Carryover and cross-contamination was negligible and 797 samples were culture positive at a cut-off of ≥105CFU/mL.

The authors concluded that the new Sysmex UF-5000 showed high diagnostic accuracy in UTI-screening with a very low rate of false negatives. The instrument is capable of predicting Gram negatives with a good standard error and a high agreement with the culture, even if this performance needs further evaluation. The study was published in the September 2018 issue of the journal Clinica Chimica Acta.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A network of inflammatory molecules may act as biomarker for risk of future cerebrovascular disease (Photo courtesy of 123RF)

Simple Blood Test Could Enable First Quantitative Assessments for Future Cerebrovascular Disease

Cerebral small vessel disease is a common cause of stroke and cognitive decline, particularly in the elderly. Presently, assessing the risk for cerebral vascular diseases involves using a mix of diagnostic... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more