LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

New Methods Detect Early Onset of Alzheimer's Disease

By LabMedica International staff writers
Posted on 28 Jul 2016
Print article
Image: The Quickplex SQ 120 plate reader for electrochemiluminescence analyses (Photo courtesy of Meso Scale Discovery).
Image: The Quickplex SQ 120 plate reader for electrochemiluminescence analyses (Photo courtesy of Meso Scale Discovery).
New methods to examine the brain and spinal fluid heighten the chance of early diagnosis of Alzheimer's disease and this may have important implications for early detection of the disease, the choice of drug treatment and the inclusion of patients in clinical trials.

It has become increasingly clear that, if the disease is to be treated successfully, it must be detected early, perhaps even before symptoms are evident. Thus, there is a great need for reliable diagnostic methods so that treatment to slow or prevent the disease can begin as early as possible.

Scientists at the Karolinska Institute (Solna, Sweden) and their colleagues studied a population consisted of 243 subjects for whom Pittsburgh compound B imaging positron emission tomography (PiB PET) data and cerebrospinal fluid (CSF) data and samples were available. These were collected across seven European academic centers belonging to the Biomarkers for Alzheimer’s and Parkinson’s Disease (BIOMARKAPD) initiative. In addition, 13 with normal cognition were recruited from relatives and carers of patients.

Apolipoprotein E (APOE) genotyping was performed in a subset of 106 subjects via polymerase chain reaction (PCR) of genomic DNA extracted from EDTA-anticoagulated blood. Subjects were classified as ϵ4 allele carriers or non-carriers. Amyloid-β42, total tau, and phosphorylated tau were measured using commercially available sandwich enzyme-linked immunosorbent assays (ELISAs) (INNOTEST, Fujirebio-Europe, Gent, Belgium). Meso Scale Discovery electrochemiluminescence analyses (MSD, Rockville, MD, USA) and a novel mass spectrometry method for amyloid-β42 and amyloid-β40 were also performed.

The scientists found that the best fit was achieved when the amyloid level in the brain was compared with the ratio between the levels of amyloid42 and amyloid40 in the spinal fluid. Given this finding, the team hypothesized that the forms of β-amyloid found in the brain and spinal fluid are not completely identical. While technical factors cannot be excluded outright as contributing to measured amyloid-β42 and amyloid-β40 levels in CSF assays, even when run in the same time and place, continued discordance using centrally re-analyzed samples suggests that biological factors are also at play.

Agneta K. Nordberg. MD, PhD, a professor and the study coordinator said, “Interestingly, there was also a difference between the values measured in the brain and spinal fluid in a smaller group of patients. This may justify that, in some unclear cases, the diagnosis should include an amyloid PET scan to complement the cerebrospinal fluid sample. These findings are also important because it is increasingly common to perform amyloid-PET studies upon the inclusion of patients in new drug studies.” The study was published on July 7, 2016, in the journal Brain.

Related Links:
Karolinska Institute
Fujirebio-Europe
Meso Scale Discovery
Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more