We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Molecular Test Finds Increased Chikungunya Virus Infections

By LabMedica International staff writers
Posted on 24 Sep 2014
Print article
Image: Digitally-colorized transmission electron micrograph (TEM) depicts numerous Chikungunya virus particles, which are composed of a central dense core that is surrounded by a viral envelope. Each virion is approximately 50 nm in diameter (Photo courtesy of Cynthia Goldsmith).
Image: Digitally-colorized transmission electron micrograph (TEM) depicts numerous Chikungunya virus particles, which are composed of a central dense core that is surrounded by a viral envelope. Each virion is approximately 50 nm in diameter (Photo courtesy of Cynthia Goldsmith).
Chikungunya is an infectious disease that causes fever, rash, and for a subset of patients, chronic joint pain. Pregnant women who acquire Chikungunya infection within one week of delivery can transmit the virus to their baby, which can lead to severe infection.

Clinical laboratory testing for Chikungunya virus may involve molecular reverse transcription polymerase chain reaction (RT-PCR), which identifies the ribonucleic acid (RNA) of the virus and immunoassays, which assess blood-serum levels of the antibodies Immunoglobulin M and G (IgM and IgG).

Medial experts from Focus Diagnostics (Cypress, CA, USA) analyzed de-identified clinical results of RT-PCR and IgG/IgM tests for Chikungunya ordered by clinicians between January 1 and August 2, 2014. The investigators determined that 2,947 patient samples were tested for antibodies to the virus by Focus Diagnostics clinical laboratory between January 1 and August 2, 2014. Of this total, 82% (2,402) were tested in June and July, suggesting a surge in test volume over the summer. Another 589 RT-PCR tests were also performed on patients. Eighty-eight specimens tested by both methods were ordered and performed.

About 22% of the total tested for antibodies, were IgG and/or IgM positive, suggesting a diagnosis of Chikungunya. Most patients underwent antibody testing well after initial infection. Sixteen percent of specimens exhibited an IgG positive/IgM positive antibody pattern, compared to 5% of specimens that were IgG negative/IgM positive. In addition, the rate of IgG/IgM positive specimens increased since June. These findings suggest that most patients were tested well after initial infection with the virus.

The investigators also determined that of 589 specimens tested by RT-PCR, 168 (28%) were positive for the Chikungunya virus. All positive PCR tests were performed during or after April 2014, possibly because of increased awareness of Chikungunya infection and PCR's role in diagnosing early infection. RT-PCR is helpful for detecting the virus within the first week of infection, but less reliably afterwards.

Hollis Batterman, MD, the medical director at Focus Diagnostics, said, “Our findings suggest that PCR and antibody testing should be considered in anyone with a compatible clinical syndrome who has traveled to or lives in areas with the species of mosquitos that carry the virus. The majority of seropositive samples were IgG/IgM positive, suggesting that most patients were tested later in the onset of infection. In the absence of PCR testing, antibody IgG/IgM patterns may be useful to infer onset of illness, and potential risk of transmission if bitten by mosquitoes.” The study was presented at the 54th Interscience Conference on Antimicrobial Agents and Chemotherapy held September 5–9, 2014, in Washington DC (USA).

Related Links:

Focus Diagnostic 


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: The QIAstat-Dx Respiratory Panel Plus has received U.S. FDA clearance (Photo courtesy of QIAGEN)

New Respiratory Syndromic Testing Panel Provides Fast and Accurate Results

Respiratory tract infections are a major reason for emergency department visits and hospitalizations. According to the CDC, the U.S. sees up to 41 million influenza cases annually, resulting in several... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more