We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Rapid Diagnostic Tests Compared for Invasive Amoebiasis

By LabMedica International staff writers
Posted on 30 Oct 2013
Print article
Image: Bichrolatex-Amibe colored latex slide agglutination test for extra-intestinal amoebiasis serodiagnosis (Photo courtesy of Fumouze Diagnostic).
Image: Bichrolatex-Amibe colored latex slide agglutination test for extra-intestinal amoebiasis serodiagnosis (Photo courtesy of Fumouze Diagnostic).
Three rapid immunoassays have been compared and evaluated for the diagnosis of invasive amoebiasis in an emergency department.

Sensitive rapid diagnostic tests (RDT) contribute to an early diagnosis and thus improve the prognosis. The test should be also specific to distinguish amoebic and pyogenic abscess in order to avoid a percutaneous drainage for diagnostic purposes and a broad-spectrum antibiotherapy.

Scientists at the Military Teaching Hospital (HIA) Bégin (Saint-Mandé, France) carried out a retrospective biological records review that included 639 patients for whom three serological tests were performed. They compared a latex agglutination test (LAT) with enzyme-linked immunosorbent assay and indirect hemagglutination assay in the diagnosis of invasive amoebiasis (IA) performed from January 1, 2001, to July 1, 2012.

The three different techniques performed for each patient at laboratory of Bégin Hospital were: a latex agglutination slide test (LAT) (Bichrolatex-Amibe, Fumouze Diagnostic; Levallois-Perret, France); an enzyme linked immunosorbent assay (ELISA) (NovaTec Entamoeba histolytica IgG-ELISA, DiaSorin SPA; Saluggia, Italy); and the Fumouze Diagnostic’s indirect hemagglutination assay Amibiase HAI (IHA).

A total of 639 patients with a performed serology were included and among them 75 had at least one positive serological result. Of these 75 patients, 46 had a final diagnosis of IA, 43 with hepatic amoebiasis, two with intestinal amoebomas and one with pleuropulmonary amoebiasis and 29 patients had another final diagnosis. The LAT was statistically more sensitive than ELISA and IHA.

The authors concluded that LAT could be used in any routine clinical laboratory because it is simple to perform and does not require any special equipment. The result is achieved quickly in 15 minutes. The interpretation is easy because the bicolored positive pattern is very distinguishable from a negative brown spot. The cost remains low at approximately EUR 5.22 per test in France. The LAT is a useful screening technique in the rapid diagnosis and the management of patients with febrile hepatalgia in emergency units. However, this test should be systematically confirmed by reference techniques (ELISA, IHA). The study was published on October 11, 2013, in the journal Diagnostic Microbiology and Infectious Disease.

Related Links:

Military Teaching Hospital Bégin
Fumouze Diagnostic 
DiaSorin SPA 


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A network of inflammatory molecules may act as biomarker for risk of future cerebrovascular disease (Photo courtesy of 123RF)

Simple Blood Test Could Enable First Quantitative Assessments for Future Cerebrovascular Disease

Cerebral small vessel disease is a common cause of stroke and cognitive decline, particularly in the elderly. Presently, assessing the risk for cerebral vascular diseases involves using a mix of diagnostic... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more