LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Real-Time PCR Assay Developed for Detection of Candida

By LabMedica International staff writers
Posted on 09 Feb 2017
Vulvovaginal candidiasis (VVC) is a common condition characterized by vulvovaginal inflammation in combination with detection of one or more of several Candida species and after bacterial vaginosis, VVC is the second most common cause of vulvovaginitis.

Traditional methods for Candida species identification, including culture followed by phenotypic, genotypic, or proteomic identification can be time consuming and often do not provide species-level identification. Accurate species identification can assist in effective empirical therapies since some Candida species show resistance to first line antifungals.

Image: The QuantStudio 12K Flex real-time PCR instrument (Photo courtesy of ANDbio).
Image: The QuantStudio 12K Flex real-time PCR instrument (Photo courtesy of ANDbio).

Scientists at the ARUP Institute for Clinical and Experimental Pathology developed a real-time polymerase chain reaction (PCR) assay targeting the multi-copy ITS2 gene of six Candida species that together cause 97% of VVC cases (C. glabrata, C. albicans, C. tropicalis, C. parapsilosis, C. krusei, and C. dubliniensis). The assay is sensitive, provides species-level detection of the six most relevant Candida species, and has been validated with commercially available reagents found to be free of interfering fungal DNA.

The team evaluated the analytical sensitivity of the Candida spp. real-time polymerase chain reaction (PCR) assay, ITS2 gene copies in cultured C. albicans and C. glabrata strains were quantified using the PCR assay by comparison to a serial dilution of an ITS2-containing plasmid. Accuracy was assessed by testing 150 vaginal swab samples submitted for Chlamydia trachomatis and Neisseria gonorrhoeae testing with the Candida spp. real-time PCR assay and by comparing results to a panfungal, ITS-based sequencing test. The QuantStudio 12K Flex Real-Time PCR instrument was used for screening.

The investigators reported that of the 150 vaginal swabs, 52 (34.7%) were positive with the Candida spp. real-time PCR assay for C. albicans (82.7%), C. glabrata (11.5%), or for the other target Candida species (11.5%) with three samples co-positive with C. albicans. Overall, 31 (20.7%) tested positive with the panfungal ITS sequencing assay for either C. albicans (29, 93.5%) or C. glabrata (2, 5.1%). Agreement between the Candida spp. real-time PCR and panfungal ITS sequencing assays was 86.0% because the sequencing assay exhibited lower analytical sensitivity than the PCR assay. The study was published on January 22, 2017, in the journal Diagnostic Microbiology and Infectious Disease.


New
Gold Member
Serological Pipets
INTEGRA Serological Pipets
3-Part Differential Hematology Analyzer
Swelab Alfa Plus Sampler
New
Pan-Cancer Panel
TruSight Oncology 500
New
Gold Member
Quality Control Material
iPLEX Pro Exome QC Panel

Latest Molecular Diagnostics News

Genetic Test Could Predict Poor Outcomes in Lung Transplant Patients
09 Feb 2017  |   Molecular Diagnostics

Breakthrough Blood Test Enables Early Pancreatic Cancer Detection
09 Feb 2017  |   Molecular Diagnostics

Genomic Testing in NICU Reduces Missed Diagnoses
09 Feb 2017  |   Molecular Diagnostics



PURITAN MEDICAL