We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Urinary Antigen Test Kit Evaluated for Diagnosing Legionella Pneumonia

By LabMedica International staff writers
Posted on 24 Feb 2021
Legionellosis is caused by bacteria called Legionella. The disease has two different forms. Legionnaires’ disease is the more severe form of infection that causes pneumonia. Pontiac fever is caused by the same bacteria, but is a milder illness without pneumonia.

Various examinations are performed for the diagnosis of Legionella pneumonia, including urinary antigen tests, respiratory specimen cultures, nucleic acid detection tests, and serum antibody tests. Although culture of Legionella species from a respiratory specimen is the diagnostic gold standard, it is time consuming. L. pneumophila is divided into 15 serogroups (SG).

Image: The BinaxNOW Legionella Urinary Antigen Card. Accurate. Rapid identification of Legionnaires` disease caused by Legionella pneumophila serogroup 1 with an easy-to-use technology (Photo courtesy of Abbott).
Image: The BinaxNOW Legionella Urinary Antigen Card. Accurate. Rapid identification of Legionnaires` disease caused by Legionella pneumophila serogroup 1 with an easy-to-use technology (Photo courtesy of Abbott).

A large team of medical microbiologists and their colleagues at Kurashiki Central Hospital (Kurashiki, Japan) enrolled prospectively pneumonia patients suspected by attending physicians to have disease caused by Legionella species based on symptoms, laboratory examinations, and radiological findings, and whose urine samples could be collected, from 16 hospitals in Japan from April 2016 to December 2018.

Three urinary antigen test kits were used: the novel kit (LAC-116 Asahi Kasei Pharma Corporation, Tokyo, Japan), BinaxNOW Legionella (Binax, Abbott Park, IL, USA), and Q-line Kyokutou Legionella (Q-line, Kyokutou Corporation, Tokyo, Japan). In addition, sputum culture and nucleic acid detection tests and serum antibody tests were performed where possible. The diagnostic accuracy and correlations of the novel kit with the two existing kits were analyzed.

The scientists reported that in total, 56 patients were diagnosed with Legionella pneumonia. The sensitivities of LAC-116, Binax, and Q-line were 79%, 84%, and 71%, respectively. The overall match rate between LAC-116 and Binax was 96.8% and between LAC-116 and Q-line was 96.4%. One patient had L. pneumophila serogroup 2, and only LAC-116 showed a positive result, whereas Binax and Q-line did not.

The authors concluded that the novel kit can theoretically diagnose Legionella pneumonia due to both L. pneumophila SG1 and non-SG1, and it is therefore useful for diagnosing Legionella pneumonia. In the future, early and appropriate diagnosis of Legionella pneumonia due to non-L. pneumophila SG1 can be expected with this novel kit. The team believes that the use of this kit may improve the prognosis of Legionella pneumonia patients. The study was published on February 1, 2021 in the International Journal of Infectious Diseases.

Related Links:
Kurashiki Central Hospital
Asahi Kasei Pharma Corporation
Binax
Kyokutou Corporation



Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
HLX
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Latest Microbiology News

Blood Analysis Predicts Sepsis and Organ Failure in Children

TB Blood Test Could Detect Millions of Silent Spreaders

New Blood Test Cuts Diagnosis Time for Nontuberculous Mycobacteria Infections from Months to Hours