We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

New Monitoring System Evaluated For Antiphospholipid Syndrome Patients

By LabMedica International staff writers
Posted on 03 Nov 2016
Antiphospholipid syndrome or antiphospholipid antibody syndrome (APS or APLS), or often also Hughes syndrome, is an autoimmune, hypercoagulable state caused by antiphospholipid antibodies.

APS provokes blood clots (thrombosis) in arteries and veins as well as pregnancy-related complications such as miscarriage, stillbirth, preterm delivery, and severe preeclampsia. Patients on anticoagulant therapy with vitamin K antagonists (VKA) need frequent International Normalized Ratio (INR) monitoring. The reliability of point-of-care (POC) devices for measuring INR needs rigorous evaluation, particularly in patients with APS.

Image: The Protime InRhythm microcoagulation system kit (Photo courtesy of International Technidyne Corporation).
Image: The Protime InRhythm microcoagulation system kit (Photo courtesy of International Technidyne Corporation).

Scientists at the University of Milan (Italy) compared a POC- INR device versus the laboratory INR measurement for blood samples from 29 APS-positive and 31 APS-negative patients consecutively enrolled. Chromogenic factor X assay was used to evaluate anticoagulation. Bland–Altman difference plot for paired INR (POC versus laboratory) was used to evaluate agreement between the device and the laboratory method. The device INR relationship with factor X chromogenic assay was evaluated by orthogonal regression analysis.

The team evaluated the accuracy of the ProTime InRhythm System (International Technidyne Corporation, Piscataway, NJ, USA), which consists of an instrument and disposable cuvettes. Each cuvette consists of two PT microchannels containing human recombinant thromboplastin to analyze a patient’s sample in duplicate to ensure accurate results, and a third internal control channel that is activated each time a test is performed to verify the integrity of the reagents and proper test procedure.

The scientists found that overall, 97% of the POC device INR measurements were similar to laboratory INR values with an absolute difference less than 0.4 units. Correlation coefficient for the device INR versus factor X was −0.69, (CI 95% −0.80 to −0.52). The authors concluded that The ProTime InRhythm System is an accurate point-of-care device for measuring INR also in patients with and without APS. The study was published in the October 2016 issue of the International Journal of Laboratory Hematology.

Related Links:
University of Milan
International Technidyne Corporation

New
Gold Member
Hematology Analyzer
Medonic M32B
Portable Electronic Pipette
Mini 96
Specimen Radiography System
TrueView 200 Pro
New
Silver Member
PCR Plates
Diamond Shell PCR Plates

Latest Hematology News

Pioneering Model Measures Radiation Exposure in Blood for Precise Cancer Treatments
03 Nov 2016  |   Hematology

Platelets Could Improve Early and Minimally Invasive Detection of Cancer
03 Nov 2016  |   Hematology

Portable and Disposable Device Obtains Platelet-Rich Plasma Without Complex Equipment
03 Nov 2016  |   Hematology