Fructosamine Reference Range Established for Brazil

By LabMedica International staff writers
Posted on 14 Jan 2019
Traditional markers used in diabetes diagnosis and monitoring include fasting plasma glucose (FPG), two-hour plasma glucose (2-hPG) measured during the oral glucose tolerance test (OGTT), and glycated hemoglobin (HbA1c) levels.

The fructosamine test is used in the monitoring of diabetes mellitus, particularly in cases with restrictions on the use of glycated hemoglobin, mainly in the setting of altered red blood cell lifespan and interference by hemoglobin variants. It could also provide additional information on shorter-term glycemic control.

Image: The AU 5800 automatic analyzer (Photo courtesy of Beckman Coulter).
Image: The AU 5800 automatic analyzer (Photo courtesy of Beckman Coulter).

Scientists at the Federal University of Minas Gerais, (Belo Horizonte, Brazil) collected blood samples from 2,288, that were part of a comprehensive study and available for fructosamine testing. The team excluded from the study individuals with a previous history of diabetes (n = 161), with FPG ≥ 5.6 mmol/L (100 mg/dL) and/or 2-hPG ≥ 7.8 mmol/L (140 mg/dL) and/or HbA1c ≥ 38.8 mmol/mol, (5.7%). They also excluded individuals with microalbuminuria ≥ 20 μg/min and creatinine> 114.9 µmol/L (1.3 mg/dL).

Samples were collected after a 12-h fasting period. The OGTT was conducted in all participants included in the present study. Samples were stored at −80 °C. Serum fructosamine levels were determined by the colorimetric nitroblue tetrazolium method in an AU 5800 automatic analyzer. The scientists proposed that the reference interval should be 186 to 248 μmol/L for women and 196 to 269 μmol/L for men. Fructosamine levels were higher in men than in women and in the non-white population and had a negative correlation with the body mass index.

The authors concluded that their study represents the first effort to establish a reference range for fructosamine levels in the Brazilian population. The report, which used the ELSA-Brazil baseline as a source of data, might contribute to future work on the diagnosis and monitoring of diabetes mellitus (DM), especially in situations when HbA1c and OGTT cannot be used. The study was published in the January 2019 issue of the journal Practical Laboratory Medicine.

Related Links:
Federal University of Minas Gerais


Gold Member
Hybrid Pipette
SWITCH
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Autoimmune Liver Diseases Assay
Microblot-Array Liver Profile Kit
HBV DNA Test
GENERIC HBV VIRAL LOAD VER 2.0

Latest Clinical Chem. News

New Blood Test Index Offers Earlier Detection of Liver Scarring
14 Jan 2019  |   Clinical Chem.

Electronic Nose Smells Early Signs of Ovarian Cancer in Blood
14 Jan 2019  |   Clinical Chem.

Simple Blood Test Offers New Path to Alzheimer’s Assessment in Primary Care
14 Jan 2019  |   Clinical Chem.