We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Medica 2024 Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

New Guideline Approved for Evaluation of Between-Reagent-Lot Variation

By LabMedica International staff writers
Posted on 11 Nov 2013
A document details a new guideline recommended for use by clinical laboratories in their methods for evaluating performance of new reagent lots.

As changes in measurement procedure performance (MPP) may occur with a change in reagent lot, good laboratory practice includes verification of the consistency of patient sample results when introducing each new lot. The Clinical and Laboratory Standards Institute (CLSI; Wayne, PA, USA) has now published “EP26-A—User Evaluation of Between-Reagent Lot Variation; Approved Guideline,” a document that provides guidance on evaluation of new analytical reagent lots. EP26-A provides laboratory users with a protocol to evaluate the consistency of patient sample results compared to the reagent lot currently in use. It uses patient samples to help users detect significant changes in MPP due to reagent lot changes and to confirm-before-use that patient sample results are consistent between the two lots. Also, although this guideline is intended for the clinical laboratory and does not provide detailed procedures for reagent manufacturers, reagent manufacturers can use this document to understand the types of verification studies that may be performed in their customers’ laboratories.

“Verifying the performance of a new reagent lot is a common task in the laboratory. Since the need to verify a new lot can occur at any time, on any day, and often needs to be accomplished on short notice, the protocol used must be simple and quick,” notes Nils Person, PhD, FACB, document Chairholder of the EP26-A Document Development Committee, and Senior Clinical Consultant at Siemens Healthcare Diagnostics Inc. in Flanders (NJ, USA). “To date, there has not been standardized guidance on how best to approach this task. EP26-A provides the needed guidance to verify the performance of a new reagent lot within the practical constraints of the clinical laboratory.”

Related Links:

Clinical and Laboratory Standards Institute



Gold Member
Antipsychotic TDM Assays
Saladax Antipsychotic Assays
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Free Human Prostate-Specific Antigen CLIA
LIAISON fPSA
New
Urine Strips
11 Parameter Urine Strips

Latest Clinical Chem. News

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Screening Tool Detects Multiple Health Conditions from Single Blood Drop

Integrated Chemistry and Immunoassay Analyzer with Extensive Assay Menu Offers Flexibility, Scalability and Data Commutability