Rapid Blood Test Detects Myocardial Infarction

By LabMedica International staff writers
Posted on 22 Mar 2011
A sensitive assay has been used to detect myocardial infarction (MI) within two hours of a patient being admitted to hospital.

An increase in the concentration of troponin in the blood is used to detect whether patients with acute coronary syndrome (ACS) have myocardial infarction and this can be used as a diagnostic marker.

A study performed at the Catharina Hospital, (Eindhoven, The Netherlands), examined the concentration of troponin in 157 patients with suspected non-ST elevated ACS. Blood was drawn on arrival (T0) and 2 (T2), 6 (T6) and 12 (T12) hours later. Levels of cardiac troponin I, creatine kinase–myocardial band fraction (CK-MB) and myoglobin were measured on an immunochemistry analyzer. The assay for troponin was the second-generation TnI-Ultra troponin kit and all tests were analyzed on the manufacturer's Advia Centaur analyzer, (Siemens Healthcare Diagnostics; Erlangen, Germany).

The TnI-Ultra troponin kit is a second-generation, high-sensitivity test with a 10% coefficient of variation (CV) at 0.05 μg/L and a troponin concentration of 0.06 μg/L at the 99th percentile of a reference population. The 99th percentile was established on 221 samples from outpatients with no history of myocardial disease. At T2, a troponin concentration above the MI cutoff is 87% sensitive and 100% specific for MI detection. A difference of more than 30% between the troponin measurements at T0 and T2 in the absence of an absolute troponin increase above the 99th percentile of a reference population was also considered indicative of MI, the sensitivity increases to 100% and specificity decreases to 87%.

The authors concluded that by using a sensitive troponin assay and simple algorithms, the diagnosis of MI can be determined within two hours after arrival at the emergency department, and the measurement of myoglobin and creatine kinase–MB has no added value. The study was published in March 2011 in the American Journal of Clinical Pathology.

Related Links:
Catharina Hospital
Siemens Medical Solutions Diagnostics


Gold Member
Chagas Disease Test
CHAGAS Cassette
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Dermatophytosis Rapid Diagnostic Kit
StrongStep Dermatophytosis Diagnostic Kit
New
HIV-1 Test
HIV-1 Real Time RT-PCR Kit

Latest Clinical Chem. News

Carbon Nanotubes Help Build Highly Accurate Sensors for Continuous Health Monitoring

Paper-Based Device Boosts HIV Test Accuracy from Dried Blood Samples

AI-Powered Raman Spectroscopy Method Enables Rapid Drug Detection in Blood



Sekisui Diagnostics UK Ltd.