We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Medica 2024 Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Automated Immunoassay for Testosterone Evaluated

By LabMedica International staff writers
Posted on 21 Feb 2011
A new electrochemiluminescence testosterone immunoassay has been evaluated and compared with existing methods.

The competitive immunoassay uses high affinity sheep monoclonal testosterone-specific antibody, which is complexed with the serum samples, and after processing the chemiluminescent emissions are measured by a photomultiplier.

Scientists at the University Medical Center Göttingen, (German), collaborated with others medical centers to evaluate the second-generation electrochemiluminescence assay and compare it to a validated assay. The scientists investigated the within-run precision, total precision, and method comparisons to the former immunoassay and the liquid chromatography tandem mass spectrometry (LC-MS/MS) assay. They were also interested in establishing reference intervals for adults and children. Special attention was paid to females with acute renal failure.

The within-run precision and total precision were determined using five different and site-specific human serum pools and two quality control samples. The within-run imprecision ranged from 12.8 μg/L, (0.9%) to 0.23 μg/L (5.2%), and total imprecision ranged from 12.7 μg/L (2.2%) to 0.22 μg/L (8.5%). The recovery according to quality control sample target values was 2.51 μg/L (95.4%) at one center, and 6.30 μg/L (103.6%) at another.

The new Elecsys Testo II assay (Roche Diagnostics GmbH, Mannheim, Germany) was compared against the former Roche Elecsys Testo assay and to a validated LC-MS/MS assay. Precision was improved especially at concentrations below 2.0 μg/L when compared to the former Elecsys Testo assay. The measuring range of 0.12 μg/L to 15.0 μg/L fulfils clinical needs. The new Elecsys Testo II assay demonstrated superior agreement in comparison to the validated LC-MS/MS method indicating an improved specificity.

Surprisingly, some high testosterone concentrations were found in samples from female patients, as confirmed by LC-MS/MS, as these individuals were suffering from polycystic ovary (PCO) syndrome or even androgen-producing tumors. The authors noted that overestimated values, especially with the former Elecsys immunoassay as compared to LC-MS/MS, were found to be from patients suffering from end-stage renal disease undergoing hemodialysis. The study was published in February 2011, in Clinical Biochemistry.

Related Links:
University Medical Center Göttingen
Roche Diagnostics



Gold Member
Hematology Analyzer
Swelab Lumi
Antipsychotic TDM AssaysSaladax Antipsychotic Assays
New
Histamine ELISA
Histamine ELISA
New
Gold Member
Pharmacogenetics Panel
VeriDose Core Panel v2.0

Latest Clinical Chem. News

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Screening Tool Detects Multiple Health Conditions from Single Blood Drop

Integrated Chemistry and Immunoassay Analyzer with Extensive Assay Menu Offers Flexibility, Scalability and Data Commutability