We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Hand-Held Analyzer Provides Critical Sepsis Information in 11 Minutes at POC

By LabMedica International staff writers
Posted on 20 Jun 2022
Print article
Image: Nanōmix eLab system utilizes patented multi-plex test cartridge technology (Photo courtesy of Nanomix)
Image: Nanōmix eLab system utilizes patented multi-plex test cartridge technology (Photo courtesy of Nanomix)

Sepsis, one of the leading causes of death, occurs when the immune system’s response to an infection spirals out of control. This can cause organ failure and other internal damage, and even death. For patients in sepsis, time to diagnosis is critical. Getting appropriate treatment right away leads to survival rates of roughly 80%. But for each hour that treatment is delayed, mortality rates increase by approximately 8%. Conventional sepsis tests can take hours or even days to generate results - far too long for optimal patient care. They are also expensive and must be run by skilled technicians in a hospital laboratory. Patients in sepsis would fare better with rapid, point-of-care testing. Now, a 11-minute critical infection test for use with a mobile, hand-held analyzer gives healthcare professionals more comprehensive information to make a sepsis diagnosis.

Nanōmix, Inc.’s (San Leandro, CA, USA) eLab system is a rapid, easy-to-use, quantitative detection platform that performs a range of in vitro diagnostic assays. The platform consists of a hand-held analyzer and a disposable cartridge. The Nanōmix eLab system utilizes patented multi-plex test cartridge technology designed to broadly impact healthcare delivery by bringing diagnostics to the point of initial patient interaction, whether in the hospital or in pre-hospital, remote or alternate-care settings. The analyzer utilizes a proprietary nano-biosensor with multiple detection electrodes to generate multiple electrochemical assay results from a single patient sample. The Nanomix eLab system offers a variety of benefits, including results in minutes, lower cost, and portability, while providing accurate, quantitative results comparable in quality to those provided by central lab testing.

Nanōmix’s first assays address the critical needs for faster diagnosis of critical infections as well as the rapid identification of current and prior SARS-CoV-2 infection. Nanōmix’s 11-minute critical infection test for use with its handheld eLab analyzer covers three key biomarkers - lactate, procalcitonin (PCT), and C-reactive protein (CRP). First responders and other providers can use the Nanomix test for quick, on-the-spot assessment and triage of patients no matter where they are. Information that previously took hours to get through confirmatory testing is now available to clinicians dealing with patients suffering complex and non-specific symptoms. In 2019 Nanomix received CE Mark for this test, which is undergoing FDA 510(k) review and is currently the only test for the procalcitonin marker that can be performed outside of a laboratory. Additionally, Nanomix has received the EU Quality Management System Certificate under the new In Vitro Diagnostic Medical Devices Regulation (IVDR) for its eLab analyzer.

Related Links:
Nanomix Corporation 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more