We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Biomarkers Associated with Major Bleeding in Patients with Atrial Fibrillation

By LabMedica International staff writers
Posted on 16 Nov 2021
Print article
Image: The BioMark HD real-time Polymerase Chain reaction (PCR) platform (Photo courtesy of Fluidigm)
Image: The BioMark HD real-time Polymerase Chain reaction (PCR) platform (Photo courtesy of Fluidigm)
Atrial fibrillation (AF) is associated with a five-fold increased risk of thromboembolisms, mainly stroke, independently of other risk factors. Accurate assessment to balance the risk of stroke and systemic embolic events (S/SEE), against the risk of major bleeding is therefore an important therapeutic goal in the clinical management of these patients.

Age, prior hemorrhage, severe renal disease, and anemia (hemoglobin) have been independently associated with an increased risk of major bleeding in patients with AF. The use of different combinations of these mainly clinical variables has resulted in at least five validated risk scores for better prediction of bleeding events in patients with AF.

Medical Scientists at Uppsala University (Uppsala, Sweden) explored associations between a wide range of biomarkers and bleeding risk in patients with AF on oral anticoagulants (OAC). Biomarkers were analyzed in a random sample of 4,200 patients, 204 cases with major bleedings. The replication cohort included 344 cases with major bleeding and 1,024 random controls.

The plasma concentrations of high-sensitivity cTnT-hs, NT-proBNP, and GDF-15 were determined by Roche immunoassays using a Cobas Analytics e601 (Roche Diagnostics, Rotkreuz, Switzerland). Interleukin 6 (IL-6) was analyzed using the high-sensitivity sandwich ELISA immunoassay (R&D Systems Inc, Minneapolis, MN, USA) and Cystatin C with the ARCHITECT system ci8200 (Abbott Laboratories, Abbott Park, IL, USA) using the particle-enhanced turbidimetric immunoassay (PETIA) from Gentian Diagnostics ASA (Moss, Norway).

The proteomic analyses were performed with the high-throughput Proximity Extension Assay (PEA) technique using the Target 96 Multiplex CVD II, CVD III, and Inflammation panels (Olink Proteomics, Uppsala, Sweden), which together simultaneously measured 276 selected proteins in plasma potentially related to CVD and inflammation. The PEA technology uses pairs of antibodies equipped with DNA reporter molecules When binding to their correct targets, antibody pairs give rise to new DNA amplicons each ID-barcoding their respective antigens. The amplicons are subsequently quantified using the Fluidigm BioMark HD real-time PCR platform (Fluidigm, South San Francisco, CA, USA).

The investigators reported that out of 268 proteins, nine biomarkers were independently associated with bleeding in both cohorts. In the replication cohort a significant linear hazard ratios per interquartile range were confirmed for these biomarkers: cytokine GDF-15, cTnT-hs, osteopontin (OPN), ephrin type-B receptor 4 (EphB4), TNF-R1, TNF-R2, soluble urokinase plasminogen activator receptor (suPAR), TRAIL-R2, and osteoprotegerin (OPG).

The authors concluded that in patients with AF on OAC, GDF-15, cTnT-hs, and seven novel biomarkers were independently associated with major bleedings and reflect pathophysiologic processes of inflammation, apoptosis, oxidative stress, vascular calcification, coagulation, and fibrinolysis. Investigations of the utility of these markers to refine risk stratification and guide the management of patients at high risk of bleeding are warranted. The study was published on the November 2021 issue of the Journal of Thrombosis and Haemostasis.

Related Links:
Uppsala University
Roche Diagnostics
R&D Systems
Abbott Laboratories
Gentian Diagnostics
Olink Proteomics
Fluidigm


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Molecular Diagnostics

view channel
Image: The fastGEN BCR::ABL1 Cancer kit offers a way to personalize treatment strategies for leukemia (Photo courtesy of BioVendor MDx)

First of Its Kind NGS Assay for Precise Detection of BCR::ABL1 Fusion Gene to Enable Personalized Leukemia Treatment

The BCR::ABL1 fusion gene plays a key role in the pathogenesis of several blood cancers, particularly chronic myeloid leukemia (CML). This gene results from a chromosomal translocation that causes constitutive... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ASTar System has received US FDA 510(k) clearance (Photo courtesy of Q-linea AB)

Automated Sepsis Test System Enables Rapid Diagnosis for Patients with Severe Bloodstream Infections

Sepsis affects up to 50 million people globally each year, with bacteraemia, formerly known as blood poisoning, being a major cause. In the United States alone, approximately two million individuals are... Read more

Pathology

view channel
Image: The new method is quick and easy, and can also be used by non-medical personnel. (Photo courtesy of Zoratto et al. Advanced Science 2024, edited)

New Blood Test Device Modeled on Leeches to Help Diagnose Malaria

Many individuals have a fear of needles, making the experience of having blood drawn from their arm particularly distressing. An alternative method involves taking blood from the fingertip or earlobe,... Read more