We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Novel Flu Test Developed to Speed Up Treatment

By LabMedica International staff writers
Posted on 20 Apr 2017
Print article
Image: The FilmArray multiplex polymerase chain reaction system used for point-of -care diagnosis of acute respiratory diseases (Photo courtesy of bioMérieux).
Image: The FilmArray multiplex polymerase chain reaction system used for point-of -care diagnosis of acute respiratory diseases (Photo courtesy of bioMérieux).
A novel way of using a swab test has been developed which can rapidly diagnose influenza and other viral infections in patients with severe respiratory conditions, resulting in shorter courses of antibiotics and less time in hospital.

Rapid point-of-care testing (POCT) for respiratory viruses might improve clinical care by reducing unnecessary antibiotic use, shortening length of hospital stay, improving influenza detection and treatment, and rationalizing isolation facility use; however, insufficient evidence exists to support its use over standard clinical care.

Doctors and their colleagues at University Hospital Southampton enrolled adults, aged equal to or over 18 years within 24 hours of presenting to the emergency department or acute medical unit of a large UK hospital with acute respiratory illness or fever higher than 37.5 °C for less than seven days duration, or both, over two winter seasons. Patients were randomly assigned (1:1), via an internet-based allocation sequence with random permuted blocks, to have a molecular POCT for respiratory viruses or routine clinical care.

Of the 301 (84%) of 360 patients in the POCT group received antibiotics compared with 294 (83%) of 354 controls and mean duration of antibiotics did not differ between groups (7·2 ± 5.1 days). The investigators found that 50/301(17%) of patients treated with antibiotics in the POCT group received single doses or brief courses of antibiotics (less than 48 hours) compared with 26 (9%) of 294 patients in the control group. Mean length of stay was shorter in the POCT group (5.7 ± 6·3 days) than in the control group (6·8 ± 7.7 days).

The authors concluded that patients who had the point-of-care test got the right treatment for their lung condition faster. In addition, patients who tested positive for influenza in the point-of-care testing group were appropriately isolated in a side room and given antiviral medication more often and sooner than those in the standard care group.

Tristan W Clark, MD, an associate professor in infectious diseases and senior author of the study, said, “My vision is that anyone who comes into hospital with an acute respiratory condition will receive this point-of-care test as soon as they come through the hospital door. It tells us immediately what virus the person has so, for example, if they have influenza they can be isolated in a side room and given antiviral drugs without delay.” The study was published on April 6, 2017, in the journal Lancet Respiratory Medicine.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more