Device Offers Potential for More Effective Blood Disorders Diagnostics

By LabMedica International staff writers
Posted on 23 Aug 2016
Researchers have developed a microfluidic device with fixed endothelial cells to mimic cellular and vascular flow conditions inside a patient’s body, which could help monitor blood clot formation, diagnose effectiveness of anti-platelet therapy, and prevent dysfunctional hemostasis.

When in dysfunction, the vascular endothelium (tissue that lines the blood vessels) plays a major role in the development of many diseases because endothelial cells are sensitive to blood flow and interact with blood cells through surface molecules. In normal hemostasis, the endothelium prevents life-threatening blood loss and clot formation, but dysfunction or inflammation may result in aberrant blood coagulation leading to blockages or hemorrhage.

Image: The new device emulates the interface between the endothelium and circulating blood, opening new doors to diagnosing blood clotting diseases caused by dysfunction or inflammation of endothelial cells, which line all blood vessels and influence the process of hemostasis (Image courtesy of the Wyss Institute at Harvard University).
Image: The new device emulates the interface between the endothelium and circulating blood, opening new doors to diagnosing blood clotting diseases caused by dysfunction or inflammation of endothelial cells, which line all blood vessels and influence the process of hemostasis (Image courtesy of the Wyss Institute at Harvard University).

"Abnormal blood coagulation and platelet activation are major medical problems and the ways we study them now are overly simplified," said Prof. Donald Ingber, MD, PhD, founding directlor of the Wyss Institute for Biologically Inspired Engineering at Harvard University (Boston, MA, USA), "Clinicians currently do not have tools to monitor hemostasis that take into account physiologically important interactions between endothelial cells and flowing blood."

The crucial interface between endothelial cells and circulating blood has not been replicated in a practical diagnostic device due to the challenge of incorporating living endothelial cells into a robust testing tool. In the new study, a Wyss Institute team led by Prof. Ingber has discovered that endothelial cells need not be “living” in order to confer their effects on blood coagulation. By microengineering tiny hollow channels lined by chemically fixed human endothelial cells that mimic cellular and vascular flow conditions inside a patient’s body, a new device developed by the team could monitor blood clot formation and diagnose effectiveness of anti-platelet therapy.

"It’s a bioinspired device that contains the endothelial function of a diseased patient without having actual living cells, and this greatly increases the robustness of the device," said first author Abhishek Jain, PhD, assistant professor at Texas A&M University, former Wyss Institute postdoctoral fellow.

This blood coagulation diagnostic can even be used to study the effects of endothelial inflammation on the formation of blood clots, which is highly relevant in patients suffering from atherosclerosis.

"This is one of the first examples of how a microfluidic cell culture system could have added value in clinical diagnostics,” said study co-author Andries van der Meer, PhD, former Wyss Institute postdoctoral fellow, now assistant professor at University of Twente, The Netherlands, “Using chemically fixed tissue that is no longer alive offers a clear, low-risk path toward further testing and product development."

A previous study by Prof. Ingber and team showed that recreating the physicality and blood flow of vasculature within microfluidic channels allowed them to predict precise times that blood might clot, with potential applications in real-time monitoring of patients receiving intravenous anticoagulants in order to prevent complications such as stroke and vascular occlusion. The new device adds another layer of complexity by embedding the functionality of the vascular endothelium within a diagnostic tool that might be manufactured, stored, and shipped for clinical use, which was not considered possible.

"Our efforts to mimic the vascular system in a meaningful way within a microfluidic device has led to two avenues of technology development," said Prof. Ingber, "Together they represent a new suite of physiologically relevant microdevices."

The study, by Jain A et al, was published online July 27, 2016, in the journal Biomedical Microdevices.

Related Links:
Wyss Institute for Biologically Inspired Engineering


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
One Step HbA1c Measuring System
GREENCARE A1c
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Latest Hematology News

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

First Affordable and Rapid Test for Beta Thalassemia Demonstrates 99% Diagnostic Accuracy

Handheld White Blood Cell Tracker to Enable Rapid Testing For Infections